Product Introduction
The iES-ICS62600INA customizable 600kW CCS2 dual-gun DC charger is our flagship all-in-one high-power charging solution for demanding commercial deployments. Optimized for large public charging stations, highway service areas and massive commercial parking premises, this unit also works well within logistics hubs and roadside charging sites. It delivers dependable ultra-high-power charging for passenger EVs and heavy-duty commercial electric vehicles.
This flagship charging station adopts integrated construction with flexible power tuning. It is fitted with high-efficiency charging modules, intelligent power-control units, power switching components and OCPP compatible charge management modules. It integrates 4G wireless modules, high-accuracy energy meters, a 7-inch HMI touch display and CCS2 charging plugs. The IP55 outdoor cabinet ensures stable performance under long-duration heavy load. Customization for cabinet housing, brand logo and touchscreen UI is available for flagship commercial charging projects.

Product Features
- Central-controlled Compact All-in-one Layout: Our flagship 600kW integrated DC charger uses compact central-control architecture for rapid site deployment. It enables concurrent charging for multiple vehicles and meets ultra-high-power charging demand for heavy-duty trucks and off-road machinery.
- Premium High-Efficiency & Energy-Saving Performance: Weighted system efficiency ≥96.5% under heavy continuous load, satisfying Class 1 energy-saving criteria.
- 108-Item Active-Oriented Safety Controls: Real-time deep-level communication with vehicle BMS, dynamic power allocation and comprehensive battery health monitoring. Safety protection shifts from passive alarm to proactive risk prevention.
- Ultra-Wide Scenario & Voltage Adaptability: DC output 200–1000V, constant-power zone 300–1000V, compatible with passenger EVs, heavy trucks and mining off-road vehicles.
- AI Intelligent Operation & Maintenance: Embedded AI self-check function and remote OTA upgrades support fault prediction and remote troubleshooting, substantially improving O&M productivity for large-scale charging infrastructure.
- Full Electrical Safety Safeguards: Real-time risk detection and instant fault cut-off against overvoltage, undervoltage, overload, short-circuit, electric leakage and overheating. Emergency stop and power-off trigger when cabinet doors open.
Technical Specifications
| Basic Data | Product Name | High‑Power Integrated DC Charger | |||||
| Models | iES‑ICS62240 | iES‑ICS62320 | iES‑ICS62360 | iES‑ICS62400 | iES‑ICS62480 | iES‑ICS62600 | |
| Rated Power | 240 kW | 320 kW | 360 kW | 400 kW | 480 kW | 600 kW | |
| Housing Material | High‑Strength Galvanized Sheet, Anti‑corrosion and Rust‑proof | ||||||
| Structural Type | Integrated | ||||||
| Dimensions (cm) | 85*88*190 | ||||||
| Connection Method | Connection Method C, Charging Mode 4 | ||||||
| Charging Gun | CCS2 ×2 Optional: CCS2 ×1 + GB/T ×1 Optional: GB/T ×2 | ||||||
| Electrical Specifications | Input Voltage / Frequency | AC 400 V ± 15%/50 ± 1Hz | |||||
| Output Voltage | DC 200 ~ 1000 V | ||||||
| Constant Power Range | DC 300 ~ 1000 V | ||||||
| Max. Output Current (Dual Guns) | MAX 800 A | ||||||
| Auxiliary Power Supply | 12 V ± 5% | ||||||
| Voltage Regulation Accuracy | ≤ ± 0.5% | ||||||
| Current Regulation Accuracy | ≤ ± 1% | ||||||
| Voltage Ripple Factor | Peak ≤ 0.5 | ||||||
| Accuracy Class | Level 1.0 | ||||||
| Standby Power Consumption (Whole Unit) | ≤ 30W | ||||||
| Input Power Factor | ≥ 0.99 | ||||||
| Noise | ≤ 65 dB | ||||||
| Mean Time Between Failures (MTBF) | ≥ 500000 h | ||||||
| Insulation / Dielectric Strength | 2200 V AC / 50 Hz 10 mA, 1 Minute Without Breakdown | ||||||
| Efficiency | First‑Level Energy Efficiency / Second‑Level Energy Efficiency (Optional) | ||||||
| Environmental Specifications | Operating Temperature | ‑25℃ ~ 65℃, It Should Be Used At a Reduced Capacity Above 50℃. | |||||
| Operating Humidity | 5% ~ 95% RH | ||||||
| Operating Altitude | ≤ 2000 m, For Distances Over 2000 Meters, The Usage Must be Reduced. | ||||||
| Protection Level | IP55 | ||||||
| Cooling Method | Intelligent Forced Air Cooling | ||||||
| Storage Temperature | ‑40℃ ~ 70℃ | ||||||
| Safety Protection | Input Protection | Input Overvoltage/Undervoltage Protection | |||||
| Output Protection | Output Overload/Short Circuit Protection | ||||||
| Equipment Safety Protection | Electrical Leakage, Grounding, Environmental Over‑temperature, Lightning Protection, Door Opening Power‑off Protection | ||||||
| Charging Process Protection | Emergency Stop, Insulation Detection, Gun Head Locking, Gun Head Over‑temperature Protection | ||||||
| Human‑Machine Interaction | Status Display | LED Three‑color Indicator Light | |||||
| LCD Screen | 7‑inch Color LCD Screen (Optional) | ||||||
| Communication Interface | 4G / 5G, Ethernet | ||||||
| Start Method | Swiping RFID Card, Scanning QR Code | ||||||
| Smart / Intelligent Functions | Automatic Power Distribution, OTA Upgrade, Charging Reservation, Scheduled Charging | ||||||
Certificates

2. Fault Handling: Remote diagnosis is adopted for all equipment faults to quickly solve software, communication and common hardware abnormalities for flagship charging units.
3. Shipping & Cost Rule: We offer free replacement parts and cover one-way China outbound freight for valid warranty issues. Local customs fees and return shipping are customer obligations.
4. Warranty Exclusion: Free warranty excludes failures caused by manual operation errors, non-standard installation, unstable grid environment, lightning damage and external physical damage.
Project Cases
All product lines support remote diagnosis and O&M services. Compatible with diverse vehicle fleets, our solutions effectively boost operational efficiency for charging sites. To date, Jicheng Zhitong has delivered numerous DC Chargers to Europe, Indonesia and the Central‑Eurasia region. Backed by dedicated service teams and sufficient spare‑part inventories, we keep supplying reliable “Jicheng‑made” charging equipment to overseas clients.